Shield Conventional Fire Alarm Control Panel Manual

Changes contact positions on appropriate common relays.
Shield conventional fire alarm control panel manual. Our systems can be used in many industrial properties. E fs1004 10 zone conventional fire alarm control panel 10 class b idc s and 4 class b nacs 120v ac add g for gray cabinet or r for red cabinet. 1 6 fire alarm systems code of practice this manual is not designed to teach fire alarm system design. Shield fire safety security ltd unit 3 endeavour drive basildon essex ss14 3wf.
Rs ppu remote station system protected premises unit ss supervisory. The edwards fireshield fire alarm family consists of 3 5 and 10 zone conventional fire alarm control panels integrated dact dialer serial annunciator modules and serial remote relay modules. Included within this range are beacons call points control panels detectors and much more. The fireshield family is ideal for both new and retrofit.
Add d for installed dialer 3 5 and 10 zone panels only. En54 part 2 clause 7 8 test condition. Wf waterflow alarm. In normal mode the control panel monitors the system.
We have helped many companies utilize our effective fire fighting solutions to enhance fire protection systems. Waterflow switches uoxx. The panels have the following optional features as standard. When this happens the panel.
The panel operates in normal mode in the absence of any alarm supervisory trouble or monitor events. Fireshield fire alarm system. The panel operates in off normal mode any time an event is introduced into the system. All of these components are microprocessor controlled.
The eaton conventional fire alarm system is certified to en54 part 2 and part 4 and is designed to meet the recommendations in bs5839. Gate valves water level switches temperature switches carbon monoxide alarm residential fire alarm control units etc. Shield global provides conventional products from the renowned legacy series. This installation manual must not be left accessible to the user.
The range consists of 2 4 and 8 zone control panels. All panels have been designed to offer high standards of performance reliability and quantity and comply fully with bs5839 part 4 1988 and en 54 parts 2 and 4. En54 part 2 clause 10 control of fire alarm routing equipment en54 part 2. Fire alarm devices.
M manual fire alarm. E fs302rd is a red fireshield panel with installed dialer. The firetec sensa alarmsense range consists of a series of conventional fire alarm control panels that comply with european standards en54 2 and en54 4 fire detection and fire alarm systems control and indicating equipment.