Server Room Temperature And Humidity Requirements

The information technology equipment can tolerate a considerable range of temperature and humidity as described in the server specifications for each server.
Server room temperature and humidity requirements. Room alert 32e is avtech s main solution which can be used to deploy sensors throughout your server room to track conditions. Temperature and humidity sensors are typically deployed in. In a data center or computer room maintaining ambient relative humidity levels between 45 and 55 is recommended for optimal performance and reliability. The recommended temperature and humidy are shown in table 1.
Ambient server room monitoring or data center monitoring is the environmental monitoring of the room for its humidity and temperature levels. In late 2005 we published an article outlining recommended data center temperature and humidity levels over the years that article has been one of our most popular pages and has helped thousands of customers establish monitor and maintain appropriate data center environment conditions. The computers in server rooms are usually headless systems that can be operated remotely via kvm switch or remote administration software such as secure shell ssh vnc and remote desktop. With ashrae determining that electrostatic discharge esd is a function of dew point or absolute humidity and not relative humidity tia 942 a has been updated to modify lower operating ranges for humidity based on dew point rather than relative humidity.
Avtech provides data center monitoring to monitor temperature humidity power active power flood water smoke fire room entry motion airflow and more. Relative humidity rh is defined as the amount of moisture in the air at a given temperature in relation to the maximum amount of moisture the air could hold at the same temperature. Figuring out the right temperature to run your server room at can be tricky you don t want to run the server room too hot and potentially damage equipment but you don t want to run it too cold and waste electricity and therefore money. Nov 17 2011.
A server room is a room usually air conditioned devoted to the continuous operation of computer servers an entire building or station devoted to this purpose is a data center. Generally the air conditioning system should be designed for 22 degrees c 71 6 degrees f and 45 percent relative humidity at altitudes up to 2150 m 7000 ft. An exploration of the recommended server room temperature and the issues surrounding maintaining the recommended temperature. Potential hot zones inside the server room or data center near air conditioning units to detect failure of such systems.